ABSOGER : NITROGEN GENERATORS
http://www.absoger-atmosphere-controlee-azote.com/
http://www.absoger-atmosphere-controlee-azote.com/ang/
http://www.absoger-atmosphere-controlee-azote.com/es/
     
   

For uses in industry, wine industry, food industry

NITROGEN GENERATORS are a competitive and reliable solution.

PROCESS DESCRIPTION:
The Nitrogen generation plants based on the PSA-process consist of two adsorption towers filled with carbon molecular sieve.
Compressed and purified air is passing the adsorption towers. Mainly Oxygen is adsorbed on the carbon molecular sieve and Nitrogen is leaving the tower.
During adsorption in one tower the second tower is totally regenerated just by depressurization to ambient pressure. The Oxygen enriched off gas is vented.
After about one minute adsorption in one adsorption tower the process controller is switching over to the second tower and the first one is regenerated.

USUAL PURITIES
Flammables products:……………………….......95 to 99%
Perfumes, cosmetics, tyres manufacturing… .........98 to 99,5%
Food, milk, oil, wine, water,……………..… ......99 to 99,9%
Plastics injection gas:……………….……….......99,5 to 99,9%
Pharmaceuticals:…………………………….......98 to 99,995%
Metals, laser cutting, metal treatments,
Welding protection:…………………………......99,5 to 99,9995%

absoger nitrogen generator

Characteristics :
Nitrogen flow indicated at atmospheric pressure
Air pressure : 9 bar
ambient temperature : 20°C
Nitrogen outlet pressure : 7 bars

N2 (Nm3/h)
99,99
99,9
99,5
99
98,00
97,00
95,00
Nitrogen Generator
Micro 500
0,12
0,25
0,4
0,5
0,65
0,75
0,9
Nitrogen Generator
Micro 1000
0,24
0,5
0,8
1
1,3
1,5
1,8
Nitrogen Generator
Micro 2000
0,48
1
1,6
2
2,6
3
3,6
Nitrogen Generator
Micro 4000
0,98
2,1
3,3
4,1
5,2
6
7,4


N2 Flow (Nm3/h)
 
99,99
99,9
99,5
99
98,00
97,00
95,00
Nitrogen Generator
GA 5
1,3
2,8
4,5
5,6
7,2
8,3
10
Nitrogen Generator GA 10
3,1
6,6
10
13
16
19
23
Nitrogen Generator
GA 20
5,1
10
17
21
27
31
38
Nitrogen Generator
GA 30
7,4
15
24
31
39
46
55
Nitrogen Generator
GA 40
10
21
34
42
54
63
76
Nitrogen Generator
GA 50
12
25
40
50
65
75
91
Nitrogen Generator
GA 60
14
30
48
60
76
88
108
Nitrogen Generator
GA 70
16
35
56
70
90
104
127
Nitrogen Generator
GA 80
19
41
66
83
106
123
149
Nitrogen Generator
GA 90
22
46
73
92
118
136
166
Nitrogen Generator
GA 100
24
50
80
100
129
149
181
Nitrogen Generator
GA 120
29
60
96
120
154
179
217
Nitrogen Generator
GA 150
36
76
120
150
193
223
271
Nitrogen Generator
GA 200
48
101
160
201
257
297
361
Nitrogen Generator
GA 250
63
126
201
251
321
371
452
Nitrogen Generator
GA 300
75
158
251
314
402
464
565
Nitrogen Generator
GA 400
96
202
322
402
515
595
724
Nitrogen Generator
GA 500
122
256
407
508
651
753
916
   
The Nitrogen generation plants based on the PSA-process consist of two adsorption towers filled with carbon molecular sieve.
Compressed and purified air is passing the adsorption towers. Mainly Oxygen is adsorbed on the carbon molecular sieve and Nitrogen is leaving the tower. 
During adsorption in one tower the second tower is totally regenerated just by depressurization to ambient pressure. The Oxygen enriched off gas is vented. 
After about one minute adsorption in one adsorption tower the process controller is switching over to the second tower and the first one is regenerated.
The Nitrogen generation plants based on the PSA-process consist of two adsorption towers filled with carbon molecular sieve.
Compressed and purified air is passing the adsorption towers. Mainly Oxygen is adsorbed on the carbon molecular sieve and Nitrogen is leaving the tower. 
During adsorption in one tower the second tower is totally regenerated just by depressurization to ambient pressure. The Oxygen enriched off gas is vented. 
After about one minute adsorption in one adsorption tower the process controller is switching over to the second tower and the first one is regenerated.

 

Contact absoger

 

ABSOGER Font de Tuile - RD 45 - 82100 LES BARTHES - FRANCE
Phone : +33 (0)5 63 31 63 76 - Fax : +33 (0)5 63 31 51 42 - E-mail : absoger@absoger.fr

Legal Notice
Design and realization : www.quick-info-services.com

Home ABSOGER - ABSOGER the compagny - Controlled atmosphere - ULO - Installations on site - Maintenance contracts - Control, Training - References in agriculture - References in Industry - Contact us - access - fruits& vegetables preservation : Nitrogen generators - fruits& vegetables preservation : CO2 Scrubbers - fruits& vegetables preservation : Ethylene Scrubbers - fruits& vegetables preservation : O2 - CO2 Analyzers - fruits & vegetables preservation : O2 - CO2 Automatic Controllers - In situ gas generation for Industry : Nitrogen generators - In situ gas generation for Industry : Oxygen generators - In situ gas generation for Industry : Air Freezer - In situ gas generation for Industry : Adsorption dryers - Cold Room Insulation : Controlled atmosphere room - Cold Room Insulation : Normal cold room - Cold Room Insulation : cold rooms Panels - Cold Room Insulation :Doors for cold rooms & accessories - To download the brochure ABSOGER (pdf) - Legal Notice absoger